Cleaning quality of frequently touched object surfaces
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的了解某院高频接触物体表面清洁质量,以制订有效的循证干预措施。方法2014年10月—2015年2月应用荧光胶剂对该院普通病房、手术室、重症监护病房(ICU)高频接触物体表面进行标记,每周1~2次,于患者出院前、手术结束后进行标记,清洁后检查物体表面清洁质量。结果共监测物体表面2 131处,清除1 732处,清除率为81.3%,卫生清洁质量处于合格状态。普通病区监测642处,清除率达82.1%;手术室监测650处,清除率75.8%;ICU区监测839处,清除率84.9%,3个病区物体表面清除率比较,差异有统计学意义(χ2 =19.964,P<0.001)。普通病区呼叫按钮、电开关和设备带清除率分别是51.3%、55.2%和58.5%,手术室墙和麻醉机控板、摇床器、键盘和输液泵的卫生清除率分别是38.6%、48.8%、60.0%、61.3%、68.4%,ICU设备带的清除率为65.9%,均处于不合格状态。结论该院环境卫生清洁质量总体处于合格状态,但仍有需要改进的地方,该院高频接触物体表面的清洁质量有待进一步提高。

    Abstract:

    ObjectiveTo investigate the cleaning quality of  frequently touched object surfaces in a hospital, so as to formulate effective evidencebased intervention measures.MethodsFrequently touched object surfaces in common wards, operating rooms, and intensive care unit(ICU) of the hospital between October 2014 and February 2015 were labeled by fluorescent adhesive agents 1-2 times a week, objects were labeled before patients’ discharge and at the end of operation, cleaning quality of frequently touched object surfaces were checked after routine cleaning.ResultsA total of 2 131 object surfaces were monitored, fluorescent adhesive agents on 1 732 objects were cleared, clearance rate was 81.3%,hygienic clean was qualified. 642,650,and 839 objects surfaces in common wards, operating rooms, and ICU were monitored respectively, the clearance rates were 82.1%,75.8%,and 84.9% respectively,  the clearance rates  among three wards were significantly different (χ2 =19.964,P<0.001). In common wards, fluorescent clearance rates of call buttons, power switches, and equipments were 51.3%,55.2%, and 58.5% respectively; in operating room,  fluorescent clearance rates of room wall, control panel of anesthesia machine, bedadjusting device, keyboards, and infusion pumps were 38.6%,48.8%,60.0%,61.3%,and 68.4%,respectively; in ICU, fluorescent clearance rates of equipments was 65.9%, all were unqualified.ConclusionThe environmental hygiene quality is generally qualified in this hospital, but the cleaning quality of frequently touched object surfaces needs to be further improved.

    参考文献
    相似文献
    引证文献
引用本文

罗盛鸿,左亚沙.高频接触物体表面清洁质量的调查[J]. 中国感染控制杂志,2016,15(7):515-517. DOI:10.3969/j. issn.1671-9638.2016.07.019.
LUO Shenghong, ZUO Yasha. Cleaning quality of frequently touched object surfaces[J]. Chin J Infect Control, 2016,15(7):515-517. DOI:10.3969/j. issn.1671-9638.2016.07.019.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2015-10-05
  • 最后修改日期:2016-01-23
  • 录用日期:
  • 在线发布日期: 2016-07-30
  • 出版日期:
文章二维码